Same-Day Engineers Available
Available Now
Keystone London Boiler Guides

Glow-worm Boiler Fault Codes & Error Codes

Is your Glow-worm boiler displaying an error code or refusing to start? Explore common Glow-worm boiler fault codes, including F1, F4, F22 and F28. Learn what these warnings may mean, which checks are safe for homeowners and when to contact a Gas Safe registered engineer.

Common Glow-worm fault codes
F1 F4 F5 F22 F28 F75
Search Viessmann Error Codes

Common Viessmann Boiler Fault Codes Explained

Search the fault code shown on your Viessmann boiler display. These examples cover codes found on certain Vitodens and other Viessmann control systems. The exact meaning depends on your boiler model and control generation, so always check the appropriate manufacturer documentation.

14 fault codes
F2 High Temperature / Safety Limit

Possible meaning: On certain Vitodens controls, F2 indicates that a high-temperature safety limit has operated.

Possible causes: Restricted circulation, overheating or a temperature-control problem.

Allow the boiler to remain off if overheating is suspected. Do not bypass safety controls or repeatedly reset the appliance. Arrange an engineer's assessment.
F4 Ignition / Flame Not Detected

Possible meaning: F4 can indicate burner ignition failure or that a flame has not been established on applicable models.

Possible causes: Ignition components, flame sensing, gas supply or burner-control issues.

Check the exact code in your manual. Do not interfere with gas or burner components. Persistent ignition faults require professional diagnosis.
F5 Airflow / Flue System Fault

Possible meaning: On some Viessmann systems, F5 is associated with air-pressure monitoring or the combustion-air/flue system.

Possible causes: Fan operation, air-pressure sensing, flue-related components or their controls.

Do not remove covers or investigate the flue internally. A qualified engineer should inspect combustion and flue-related faults.
F9 Burner Fan / Speed Fault

Possible meaning: F9 may indicate that the burner fan is not operating at the expected speed on certain models.

Possible causes: Fan motor, wiring, speed feedback or burner-control faults.

Fan and combustion-system checks are not homeowner repairs. Arrange professional diagnosis if the code appears.
F10 Outside Temperature Sensor Fault

Possible meaning: F10 is associated with an outside-temperature sensor short circuit on certain weather-compensated Viessmann controls.

Possible causes: Sensor, wiring or connection problems.

Check whether your system uses an outdoor sensor. Do not open electrical controls or attempt sensor wiring repairs.
F18 Outside Sensor Open Circuit

Possible meaning: F18 may indicate an interruption in the outside-temperature sensor circuit on compatible controls.

Possible causes: Disconnected wiring, sensor failure or damaged connections.

An engineer can test the sensor and its circuit. Avoid opening boiler electrical compartments.
F30 Boiler Temperature Sensor Fault

Possible meaning: On selected controls, F30 indicates a short circuit in the boiler-water temperature sensor.

Possible causes: Defective sensor, wiring or electrical connections.

This normally requires electrical testing and professional repair rather than a homeowner reset.
F38 Boiler Sensor Open Circuit

Possible meaning: F38 can indicate an interrupted boiler-water temperature sensor circuit on certain systems.

Possible causes: Sensor damage, disconnected wiring or failed connections.

Do not attempt to access internal sensors. Have the appliance assessed by a competent engineer.
F50 Hot Water Cylinder Sensor Fault

Possible meaning: F50 may indicate a short circuit in the cylinder temperature sensor on compatible systems.

Possible causes: Sensor or wiring faults affecting hot-water temperature monitoring.

This code is relevant to certain systems with a hot-water cylinder. Check your model's documentation before interpreting it.
F58 Cylinder Sensor Open Circuit

Possible meaning: F58 can indicate an interruption in the cylinder temperature sensor circuit on applicable systems.

Possible causes: Damaged sensor, wiring or connections.

An engineer should identify and test the affected sensor circuit.
F70 Coding / Control Configuration Fault

Possible meaning: On certain Viessmann controls, F70 is associated with the boiler coding card or configuration.

Possible causes: Incorrect, missing or defective coding components.

Configuration and coding repairs require an engineer familiar with the particular Viessmann control system.
F78 Coding Component Fault

Possible meaning: F78 may indicate a coding-related control fault on selected Viessmann systems.

Possible causes: Coding-card compatibility, configuration or control-related issues.

Do not alter internal boiler settings or replace control components without professional guidance.
F80 Flue Gas Temperature Sensor Fault

Possible meaning: On certain controls, F80 is associated with a short circuit in the flue-gas temperature sensor.

Possible causes: Temperature sensor or related wiring faults.

Flue and combustion-related sensor work must be left to appropriately qualified professionals.
F88 Flue Sensor Open Circuit

Possible meaning: F88 can indicate an interruption in the flue-gas temperature sensor circuit on applicable Viessmann systems.

Possible causes: Sensor damage, disconnected wiring or related electrical faults.

Do not open the appliance or inspect the flue internally. Arrange professional assessment.
No matching fault codes found. Try searching a shorter code or symptom.
Important: This is a general reference, not a universal Viessmann fault-code table. Vitodens 050-W, 100-W, 200-W and other models may use different diagnostics depending on their generation and control system. Always check the documentation for your exact appliance before acting on a code.

Can't Find Your Viessmann Fault Code?

Tell Keystone London your boiler model and the exact error displayed so our team can help with the next steps.

Contact an Engineer →
Understanding Your Boiler Display

What Does a Viessmann Boiler Fault Code Actually Mean?

Modern Viessmann boilers monitor their operation through sensors and electronic controls. When the system detects an abnormal condition, it may display a fault message, restrict operation or stop the burner. However, not every number or symbol on the display means your boiler has broken down.

1. Fault Codes

A fault code identifies a condition detected by the boiler's control system. It helps narrow down the investigation, but does not always identify the exact failed component. For example, an ignition fault may have several possible causes.

2. Safety Lockouts

A lockout is a protective shutdown that prevents normal burner operation until the fault is addressed and, where appropriate, the system is reset. Repeated lockouts should never be ignored, even if a reset temporarily restores heating.

3. Status Information

Some displays show operating temperatures, burner activity, heating modes or diagnostic information during normal use. A displayed number alone is not proof of a fault. Its meaning depends on the control panel and the operating mode selected.

What Happens When Your Viessmann Boiler Detects a Problem?

01

A condition is detected

Sensors or controls identify an operating condition outside the expected range.

02

A message appears

The display may show a code, warning or other indication, depending on the model.

03

Operation may be restricted

The boiler may continue operating, reduce functionality or enter a safety lockout.

04

The cause is investigated

The code, model details and symptoms help determine the appropriate next steps.

Why Your Exact Viessmann Model Matters

Viessmann has produced multiple boiler ranges and control generations. The same-looking code may not carry the same meaning across every appliance. Before using a fault-code guide, identify your model from the appliance documentation or accessible external identification label. Do not remove a sealed cover to find it.

Vitodens 050-W Vitodens 100-W Vitodens 200-W Other Viessmann Models

If you smell gas, suspect a combustion problem or believe the appliance is unsafe, do not attempt to reset or repair it. Follow the appropriate gas-emergency guidance.

Homeowner Troubleshooting

6 Safe Checks to Try Before Calling a Baxi Boiler Engineer

Some Baxi boiler problems have simple explanations, such as incorrect heating settings or low system pressure. Before arranging a repair, these basic checks may help you understand the issue. Only follow procedures permitted in your boiler's user manual.

01

Check the Boiler Pressure

Look at the pressure gauge or digital reading, if your model has one. Low pressure may prevent some Baxi boilers from operating normally.

Check your manual for the correct cold-system pressure range.

02

Check Your Thermostat

Make sure your room thermostat is requesting heat and is set above the current room temperature.

Check batteries if your thermostat uses them.

03

Check the Power Supply

Confirm the boiler display is illuminated and check whether other electrical appliances are working normally.

Do not open the boiler casing or investigate internal wiring.

04

Look for Visible Water Leaks

Check around accessible radiators, pipework and underneath the boiler for signs of dripping or water damage without removing covers.

Never open sealed boiler components to search for a leak.

05

Review Heating Controls

Check your programmer, heating schedule and selected operating mode. Your boiler may simply not have an active request for central heating.

Confirm that heating has not been switched off by a timer.

06

Check the Error Code & Manual

Record the exact fault code displayed and compare it with the user instructions for your Baxi model.

Only use a reset procedure if your manufacturer permits it.

Important Boiler Safety Advice

Never remove the sealed boiler casing, bypass a safety device or attempt repairs involving gas, combustion or internal electrical components. Repeatedly resetting a boiler without identifying the fault can be unsafe.

If you smell gas in Great Britain: leave the property, avoid using electrical switches or naked flames, and call the National Gas Emergency Service on 0800 111 999 from a safe location.

Still Having Problems With Your Baxi Boiler?

If the fault code keeps returning, your boiler will not restart or you suspect an internal component problem, Keystone London can help arrange professional fault diagnosis.

Contact Keystone London →
Safe Homeowner Troubleshooting

6 Things to Check Before Calling a Viessmann Boiler Engineer

Some heating interruptions are caused by straightforward issues outside the boiler itself. Before arranging a repair, these six basic checks may help you identify what is happening. Only carry out checks that are accessible and described in your boiler's user manual.

01

Check the Thermostat & Heating Schedule

Make sure your thermostat is requesting heat and that the heating programme is active. A timer setting, holiday mode or low target temperature can make a working boiler appear unresponsive.

Check: thermostat setting, schedule and heating mode.
02

Look at the System Pressure

If your system has a pressure display or gauge, check its reading against the recommended range in your model's manual. Low pressure may prevent normal heating operation. Do not top up the system unless the manufacturer's instructions explain how to do so safely.

Check: pressure reading and any visible signs of leaks.
03

Confirm the Boiler Has Power

Check whether the display is illuminated and whether other electrical appliances are working. You can also check accessible household controls, such as a clearly labelled fused spur or circuit breaker, without opening any electrical enclosures.

Check: display, accessible switch and household power.
04

Check for a Visible Frozen Condensate Pipe

During freezing weather, an external condensate pipe may become blocked by ice, causing some boilers to stop. If your manual identifies this as the issue, follow its homeowner instructions. Never use boiling water or dismantle pipework.

Check: freezing conditions and accessible external pipework.
05

Check the Hot Water & Heating Symptoms

Note whether you have lost heating, hot water or both. Also check whether the problem affects every radiator or just one room. These details can help distinguish a boiler issue from a thermostat, radiator or heating-control problem.

Check: which services and rooms are affected.
06

Record the Exact Fault Code & Model

Take a photo of the display and note the complete fault message, including any letters, numbers or symbols. Find the boiler model in your documents or on an accessible external label. This helps an engineer prepare for the correct diagnosis.

Check: fault code, model and when the issue started.

What You Should Never Attempt

Do not remove the boiler casing, interfere with gas valves, open electrical compartments, bypass safety devices or investigate internal burner and flue components. If you smell gas, suspect carbon monoxide or believe the appliance is unsafe, stop using it and follow emergency safety guidance. In Great Britain, the gas emergency number is 0800 111 999. For suspected carbon monoxide exposure, get into fresh air and seek urgent medical advice.

Still Having Trouble With Your Viessmann Boiler?

Share the model, fault code and symptoms with Keystone London so we can help you arrange the appropriate next steps.

Request Boiler Assistance →
More Boiler Troubleshooting Advice

Common Baxi Boiler Problems & Related Guides

A Baxi fault code often appears alongside a wider heating problem, such as falling water pressure, no hot water or a boiler that will not ignite. Explore our related troubleshooting guides to understand common symptoms, possible causes and when professional attention is needed.

More Boiler Fault Code Guides

Explore Fault Codes for Other Boiler Brands

Different boiler manufacturers use different fault-code systems. If your appliance isn't a Viessmann, choose the correct manufacturer below to explore common error messages, possible causes and safe next steps.

Frequently Asked Questions

Viessmann Boiler Fault Codes — FAQs

Find answers to common questions about Viessmann boiler error codes, ignition failures, resetting your boiler and identifying problems with Vitodens heating systems.

What does F4 mean on a Viessmann boiler?

On certain Viessmann Vitodens models, F4 indicates that the burner has failed to ignite or a flame has not been detected. Possible causes include ignition components, flame detection or gas supply problems.

The exact interpretation depends on the boiler model. If the fault persists, arrange professional diagnosis rather than attempting internal repairs.

What does Viessmann fault code F2 mean?

On some Viessmann controls, F2 is associated with the high-temperature safety limit. It may occur when the boiler detects overheating or a circulation-related problem.

Because overheating involves a safety function, do not repeatedly reset the boiler. Have the cause investigated by a qualified engineer.

How do I reset my Viessmann Vitodens boiler?

The reset procedure varies between Viessmann models and control generations. Some appliances have a dedicated reset control, while others use a menu-based function.

Follow the user manual for your exact model and only reset the boiler if the instructions permit it for the displayed fault. If the error returns, contact an engineer.

Why does my Viessmann boiler keep locking out?

Repeated lockouts can occur when the boiler detects an unresolved problem affecting ignition, circulation, temperature monitoring or another safety-related function.

Record the fault code and when the lockout happens. Repeated resets are not a repair and may delay diagnosis of the underlying issue.

What does F5 mean on a Viessmann boiler?

On certain Viessmann systems, F5 may relate to combustion-air monitoring, air pressure or the flue system. The exact meaning varies by model.

Do not inspect internal fan, burner or flue components yourself. These faults require an appropriately qualified engineer.

Why is my Viessmann boiler not heating the radiators?

Possible explanations include thermostat settings, heating schedules, low system pressure, circulation problems or a boiler fault.

Check the accessible heating controls and whether a fault message is displayed. Our radiator troubleshooting guide explains other common reasons radiators may remain cold.

Are Viessmann fault codes the same on every Vitodens model?

No. Viessmann fault-code meanings and display formats can differ between the Vitodens 050-W, 100-W, 200-W and different generations of those appliances.

Always use documentation that matches your exact model and control system. A generic fault-code list should not be treated as a substitute for the manufacturer's instructions.

When should I call an engineer for a Viessmann fault?

Contact an engineer when the fault persists, the boiler repeatedly locks out, there are signs of overheating or leakage, or the problem involves ignition, gas, electrical or combustion components.

For work on a gas boiler in the UK, use an appropriately Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, follow emergency safety guidance immediately.

A Note About Viessmann Vitodens Models

The fault-code examples on this page are intended as general guidance. Different Vitodens generations may use different fault messages and diagnostic procedures. Always confirm the meaning using the manufacturer's instructions for your exact boiler model. Never remove a sealed casing or attempt gas, combustion or electrical repairs yourself.

Keystone London — Boiler Assistance

Need Help With a Viessmann Boiler Fault?

Whether your Viessmann boiler is showing an error code, repeatedly locking out or failing to provide heating and hot water, Keystone London can help you arrange professional diagnosis and repair. Have your boiler model and fault code ready when contacting our team.

KEYSTONE LONDON

First Floor, 289 Brompton Road

Knightsbridge

London SW3 2DY
© 2026 Keystone London Group Limited
Company Reg: 16435424 · VAT: 494 7956 19
Website by Daniel Hayes